Diesel generators should be familiar to everyone. It is a very wide range of generators. Today I will talk to you about the topic of diesel generators. Many projects encounter many common faults when using diesel generators. What are the wrong ways to operate a diesel generator? Let ’s take a closer look at “introduction to common problems and incorrect usage of diesel generators”.



[Common faults of diesel generators]


或喷不出油 1, little or no fuel injection


(1) Air has penetrated into the oil circuit.


(2) The oil needle or oil needle body bites.


(3) The oil needle and the oil needle body are too loose.


(4) The fuel system has serious oil leakage.


(5) The fuel supply of the fuel injection pump is abnormal.


(6) Oil needle body and oil needle are rolled to death.


(1) Exclude air.


(2) Check, repair or replace.


(3) Replace the fuel injection nozzle parts.


(4) Check and fasten each joint of the oil circuit, and replace if necessary.


(5) Maintenance and adjustment


(6) Clean and repair.



压力低 2.Low fuel injection pressure


(1) The pressure regulating screw is loose.


(2) Deformation of the pressure regulating spring causes pressure to decrease.


(1) Adjust the fuel injection pressure to the specified value.


(2) Adjust or replace with a new spring.


太高 3.Injection pressure is too high


(1) The pressure of the pressure regulating spring is too large.


(2) The oil needle is stuck.


(3) Fuel injection is blocked.


(1) Adjust the pressure or replace the spring.


(2) Repair the fuel injection nozzle.


(3) Maintenance and cleaning.


4.Severe oil leakage from the injector


(1) The pressure regulating spring is broken.


(2) The seating surface of the needle body is damaged.


(3) The oil needle is bitten.


(4) Tighten the cap for a long time.


(5) The plane of the injector casing is worn out.


(1) Replace with a new spring.


(2) Replace the injector nozzle parts.


(3) Clean or replace the fuel injection nozzle parts.


(4) Replace.


(5) Grind the shell surface or replace it.


雾化不良 5. Poor atomization of the injector


(1) The needle body is deformed or worn.


(2) The seating surface of the needle body is worn or burned.


(1) Replace the injector nozzle parts.


(2) Replace the injector nozzle parts.


6.Injection into line


(1) Nozzle is blocked.


(2) The oil needle and the seat surface of the oil needle body are excessively worn.


(3) The oil needle is bitten.


(1) Clean or replace.


(2) Replace the injector nozzle parts.


(3) Clean or replace.


7. Diesel engine overheating


The surface of the injector is burnt out or blue-black.


Overhaul the cooling system and replace the injector nozzle parts.


[What are the incorrect operation methods of diesel generators]


The incorrect operation of the diesel generator will seriously affect the service life of the diesel generator. Let ’s find out what are the incorrect operation methods of the diesel generator in daily life?


Misoperation of diesel generator 1: diesel engine runs when engine oil is insufficient


In this case, due to insufficient oil supply, the surface of each friction pair is insufficiently supplied with oil, resulting in abnormal wear or burns. For this reason, before the start of the diesel generator and during the operation of the diesel engine, ensure that the engine oil is sufficient to prevent cylinder failure and tile burning failure due to lack of oil.



Diesel generator wrong operation two: emergency shutdown with load or immediate shutdown after sudden load shedding


After the diesel generator is turned off, the circulation of the cooling system water is stopped, the heat dissipation capacity is sharply reduced, and the heated parts lose cooling, which may easily cause the cylinder head, cylinder liner, cylinder block and other parts to overheat, cause cracks, or cause the piston to overextend and jam in the cylinder liner Inside. On the other hand, if the diesel generator is not cooled down at idle speed when it is stopped, the friction surface will be insufficiently oily, and when the diesel engine is restarted, it will intensify wear due to poor lubrication. Therefore, the diesel generator should be unloaded before the flameout, and gradually reduce the speed and run at no load for several minutes.


Incorrect operation of diesel generators III: Load running without warming up after cold start


When the diesel generator is cold-started, due to the large viscosity of the oil and poor fluidity, the oil supply of the oil pump is insufficient, and the friction surface of the machine is severely worn due to poor oil lubrication, and even failures such as cylinder pulling and tile burning occur. Therefore, the diesel engine should be warmed up at idle speed after the start of cooling, and run with load when the standby oil temperature reaches 40 ° C or higher; the machine should start at low speed and drive a mileage in each gear step by step until the oil temperature is normal and the fuel is sufficient Only then can it switch to normal driving.


Incorrect operation of diesel generators IV: Throttle throttle after cold start of diesel engine


If the throttle is blasted, the speed of the diesel generator will rise sharply, which will cause some friction surfaces on the machine to wear out severely due to dry friction. In addition, the piston, connecting rod, and crankshaft receive a large change in force when the throttle is bombed, causing severe impacts and easy damage to the parts.


Diesel generator wrong operation five: running under insufficient cooling water or cooling water and high oil temperature


Insufficient cooling water amount of diesel generator will reduce its cooling effect. The diesel engine will overheat because it cannot get effective cooling; too high oil temperature of cooling water and oil will also cause the diesel engine to overheat. At this time, the diesel generator cylinder head, cylinder liner, piston assembly and valve are mainly subject to heavy heating loads, and their mechanical properties such as strength and toughness decrease sharply, which increases the deformation of the parts, reduces the gap between the parts, and accelerates the wear of the parts. , In severe cases, cracks and jammed parts will also occur. Overheating the diesel generator will also worsen the combustion process of the diesel engine, make the injector work abnormally, the atomization will be bad, and the carbon deposit will increase.


The above introductions to "common faults of diesel generators" and "what are the incorrect operation methods of diesel generators" are hoped to help you understand the "common problems of diesel generators and the introduction of wrong usage methods".

下一篇:没有了 Next: Nothing Next: No

everybody is watching

  • 介绍柴油发电机组辨别冒烟颜色启动从预热开始
    Blue smoke, fire reason: It means that the engine is burning oil. There are three types of reasons: first, the piston ring goes opposite, and the oil comes in the cylinder; the second is the oil level of the oil pan of the atmosphere filter, which leads the ring. The height of the groove; Third, the gap between the duct and the valve stem is too poor. Expulsion idea: Adjust the piston ring so that the opening teeth of the ring are staggered 120 degrees or 180 degrees, and the opening teeth of the ring should avoid the piston pin hole and the side pressure is poor. Adjust the height of the oil level of the oil filter of the atmosphere filter below the height of the annular groove; if the clearance between the duct and the valve stem is too poor, replace the component and reduce the clearance. The normal mutual assistance clearance between the two is 0.0
  • 发电机租赁必须对它的操纵规程有一定的认识
    Before starting, you should check whether the fuel volume of the fuel tank is rich, and there is no oil leakage in each oil pipe and the discussion area; whether the cooling system water is rich, clean and leak-free, and whether the fan belt is tight or not. The internal combustion engine and generator drive parts should be connected and trusted. The wires of the input line are well-insulated, complete and effective in all aspects. After starting, it should run at low speed for 3 to 5 minutes. After the temperature and oil pressure wheel are normal, the initial work can be done. The generator should be no different in the speed increase. Ring, the slip ring and commutator are well brushed, no jumping and sparking phenomenon. After the operation is stable and the frequency and voltage reach the rated value, power can be supplied to the outside.
  • 同步发电机一般常见问题的处理
    The diesel engine is working normally, but the generator fails to generate electricity or the voltage is very low. This may be due to the components associated with the generator, such as: the exciter is damaged, and the excitation voltage cannot be supplied. The excitation current is taken in. The rotor's dead center residual magnetism is weakened or declining. It will make the generator unable to generate electricity or the transmission voltage is extremely low. The right to respond is usually: use an appropriate DC voltage and directly connect to the excitation winding according to the polarity Magnetization. Carefully inspect the exciter and the cyclotron rectifier, find abnormal components or windings, and replace them for restoration. The generator's transmission voltage is unstable, and
  • 小负荷柴油发电机组在工作时有哪些故障
    In the power generation industry in China, we have been working hard, pursuing the concept of quality and service, and for the sake of customers, the full power generator chooses China and your generator is a professional housekeeper. At present, the diesel generator set maintenance market refers to damage inspection and routine maintenance. Two aspects: after maintenance refers to the failure of the diesel generator, there are problems with various accessories, such as replacing the generator or

Popular information